________________________________________________________________
10 / 21
Example2: Get Brightness from TV-05 , but the Brightness command ID is error
and it is NOT in the command table.
Send (Hex Format)
Name
Lengt
h
ID Command Type
Command Value1
Value2
Value3
CR
Hex 0x38 0x30
0x35
0x67 0XD3 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name
Length ID Command Type CR
Hex 0x34 0x30
0x35
0x2D 0x0D
Example3: Get Tint from TV-0007 and this command is valid.
The Tint value is 32.
Send (Hex Format)
Name
Length
ID Command
Type
Command Value1
Value2
Value3
CR
Hex 0x38 0x30
0x37
0x67 0X65 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name
Length
ID Command
Type
Command Value1
Value2
Value3
CR
Hex 0x38 0x30
0x37
0x72 0x65 0x30 0x33 0x32 0x0D
Example4: Get Tint from TV-07 , but the Brightness command ID is error and it is NOT in the
command table.
Send (Hex Format)
Name
Length
ID Command
Type
Command Value1
Value2
Value3
CR
Hex 0x38 0x30
0x37
0x67 0XD7 0x30 0x30 0x30 0x0D
Reply (Hex Format)
Name
Length ID Command Type CR
Hex 0x34 0x30
0x37
0x2D 0x0D
Example5 Get backlight sensor from TV-0007 and this command is valid.
The lux value is 1786 (ASCII code).
Send (Hex Format)
Name
Length
ID Command
Type
Command
Value1
Value2
Value3
Value4
CR
Hex 0x39 0x30
0x37
0x67 0X6F 0x30 0x30 0x30 0x30 0x0D